1
0
This repository has been archived on 2025-11-01. You can view files and clone it. You cannot open issues or pull requests or push a commit.
Files
contaminus/README.md
2025-03-11 22:20:01 +01:00

208 lines
6.4 KiB
Markdown

# ⚠ REQUISITOS PREVIOS (SÓLO DAD)
- Descargar [MariaDB 10.6.21](https://mariadb.org/download/?t=mariadb&p=mariadb&r=10.6.21&os=windows&cpu=x86_64&pkg=msi&mirror=raiolanetworks)
- Descargar [DBeaver](https://dbeaver.io/download/)
- Descargar [Postman](https://www.postman.com/downloads/)
## Para lanzar la API con Vert.X
1. Run -> Run Configurations -> Java Application
2. Como clase principal: `io.vertx.core.Launcher`
3. Como argumentos: `net.miarma.contaminus.server.MainVerticle`
# ⚠ REQUISITOS PREVIOS (DAD + Hack4Change)
- Descargar Node.js
- Para descargar Node recomiendo fnm (Fast Node Manager) que lo podéis descargar [aquí](https://miarma.net/descargas)
- Para instalarlo: `fnm install 23.7.0`
-
## Para lanzar la web en modo desarrollador
1. Abrir terminal (normalmente en VSCode) en la carpeta ContaminUS/frontend
2. `npm install`
3. `npm run dev`
## Para transpilar la web de React a HTML/CSS/JS Vanilla
`npm run build` <br>
La encontraréis en `dist/`
# ⚙️ Script para crear la BD
```sql
USE dad;
DROP TABLE IF EXISTS gps_values;
DROP TABLE IF EXISTS air_values;
DROP TABLE IF EXISTS actuators;
DROP TABLE IF EXISTS sensors;
DROP TABLE IF EXISTS devices;
DROP TABLE IF EXISTS groups;
CREATE TABLE IF NOT EXISTS groups(
groupId INT PRIMARY KEY AUTO_INCREMENT NOT NULL,
groupName VARCHAR(64) DEFAULT NULL
);
CREATE TABLE IF NOT EXISTS devices(
deviceId INT PRIMARY KEY AUTO_INCREMENT NOT NULL,
groupId INT NOT NULL,
deviceName VARCHAR(64) DEFAULT NULL,
FOREIGN KEY (groupId) REFERENCES groups(groupId)
);
CREATE TABLE IF NOT EXISTS sensors(
sensorId INT PRIMARY KEY AUTO_INCREMENT NOT NULL,
deviceId INT NOT NULL,
sensorType VARCHAR(64) NOT NULL,
unit VARCHAR(8) NOT NULL,
status INT NOT NULL,
timestamp TIMESTAMP DEFAULT CURRENT_TIMESTAMP(),
FOREIGN KEY (deviceId) REFERENCES devices(deviceId)
);
CREATE TABLE IF NOT EXISTS actuators (
actuatorId INT PRIMARY KEY AUTO_INCREMENT NOT NULL,
deviceId INT NOT NULL,
status INT NOT NULL,
timestamp TIMESTAMP DEFAULT CURRENT_TIMESTAMP(),
FOREIGN KEY (deviceId) REFERENCES devices(deviceId)
);
CREATE TABLE IF NOT EXISTS gps_values(
valueId INT PRIMARY KEY AUTO_INCREMENT NOT NULL,
sensorId INT NOT NULL,
lat FLOAT NOT NULL,
lon FLOAT NOT NULL,
timestamp TIMESTAMP DEFAULT CURRENT_TIMESTAMP(),
FOREIGN KEY (sensorId) REFERENCES sensors(sensorId)
);
CREATE TABLE IF NOT EXISTS weather_values (
valueId INT PRIMARY KEY AUTO_INCREMENT NOT NULL ,
sensorId INT NOT NULL,
temperature FLOAT NOT NULL,
humidity FLOAT NOT NULL,
timestamp TIMESTAMP DEFAULT CURRENT_TIMESTAMP(),
FOREIGN KEY (sensorId) REFERENCES sensors(sensorId)
);
CREATE TABLE IF NOT EXISTS co_values (
valueId INT PRIMARY KEY AUTO_INCREMENT NOT NULL ,
sensorId INT NOT NULL,
value FLOAT NOT NULL,
timestamp TIMESTAMP DEFAULT CURRENT_TIMESTAMP(),
FOREIGN KEY (sensorId) REFERENCES sensors(sensorId)
);
CREATE OR REPLACE VIEW v_sensor_values AS
SELECT
s.sensorId,
s.deviceId,
s.sensorType,
s.unit,
s.status AS sensorStatus,
s.timestamp AS sensorTimestamp,
av.temperature,
av.humidity,
av.carbonMonoxide,
av.timestamp AS airValuesTimestamp,
gv.lat,
gv.lon,
gv.timestamp AS gpsTimestamp
FROM sensors s
LEFT JOIN air_values av ON s.sensorId = av.sensorId
LEFT JOIN gps_values gv ON s.sensorId = gv.sensorId;
CREATE OR REPLACE VIEW v_latest_values AS
SELECT
s.deviceId,
s.sensorId,
s.sensorType,
s.unit,
s.status AS sensorStatus,
s.timestamp AS sensorTimestamp,
av.temperature,
av.humidity,
av.carbonMonoxide,
av.timestamp AS airValuesTimestamp
FROM sensors s
LEFT JOIN air_values av
ON s.sensorId = av.sensorId
AND av.timestamp = (
SELECT MAX(timestamp)
FROM air_values
WHERE sensorId = s.sensorId
);
CREATE OR REPLACE VIEW v_pollution_map AS
SELECT
g.lat,
g.lon,
a.carbonMonoxide,
d.deviceId,
d.deviceName
FROM
gps_values g
JOIN
air_values a ON g.sensorId = a.sensorId
JOIN
sensors s ON a.sensorId = s.sensorId
JOIN
devices d ON s.deviceId = d.deviceId
WHERE
(g.sensorId, g.timestamp) IN (
SELECT sensorId, MAX(timestamp)
FROM gps_values
GROUP BY sensorId
)
AND
(a.sensorId, a.timestamp) IN (
SELECT sensorId, MAX(timestamp)
FROM air_values
GROUP BY sensorId
);
-- Insertar grupos
INSERT INTO groups (groupName) VALUES ('Grupo 1');
-- Insertar dispositivos
INSERT INTO devices (groupId, deviceName) VALUES
(1, 'Dispositivo 1'),
(1, 'Dispositivo 2'),
(1, 'Dispositivo 3');
-- Sensores para el Dispositivo 1
-- Cada dispositivo tiene un único sensor de cada tipo (GPS, Temperature & Humidity, CO)
INSERT INTO sensors (deviceId, sensorType, unit, status) VALUES
(1, 'GPS', 'N/A', 1), -- Sensor de GPS para Dispositivo 1
(1, 'Temperature & Humidity', '°C/%', 1), -- Sensor de Temp/Humidity para Dispositivo 1
(1, 'CO', 'ppm', 1); -- Sensor de CO para Dispositivo 1
-- Sensores para el Dispositivo 2
INSERT INTO sensors (deviceId, sensorType, unit, status) VALUES
(2, 'GPS', 'N/A', 1), -- Sensor de GPS para Dispositivo 2
(2, 'Temperature & Humidity', '°C/%', 1), -- Sensor de Temp/Humidity para Dispositivo 2
(2, 'CO', 'ppm', 1); -- Sensor de CO para Dispositivo 2
-- Sensores para el Dispositivo 3
INSERT INTO sensors (deviceId, sensorType, unit, status) VALUES
(3, 'GPS', 'N/A', 1), -- Sensor de GPS para Dispositivo 3
(3, 'Temperature & Humidity', '°C/%', 1), -- Sensor de Temp/Humidity para Dispositivo 3
(3, 'CO', 'ppm', 1); -- Sensor de CO para Dispositivo 3
-- Valores de GPS para los Dispositivos
-- Cada dispositivo tiene un único sensor de GPS con latitud y longitud asociada
INSERT INTO gps_values (sensorId, lat, lon) VALUES
(1, 37.3861, -5.9921), -- GPS para Dispositivo 1
(4, 37.3850, -5.9910), -- GPS para Dispositivo 2
(7, 37.3860, -5.9920); -- GPS para Dispositivo 3
-- Valores de Temperatura, Humedad y CO para los Dispositivos
-- Cada dispositivo tiene un único sensor de aire (temperatura, humedad, CO) con valores asociados
INSERT INTO weather_values (sensorId, temperature, humidity) VALUES
(2, 22.5, 45.0), -- Temperatura, Humedad para Dispositivo 1
(5, 24.5, 50.0), -- Temperatura, Humedad para Dispositivo 2
(8, 21.0, 44.0); -- Temperatura, Humedad para Dispositivo 3
INSERT INTO co_values (sensorId, value) VALUES
(3, 0.02), -- CO para Dispositivo 1
(6, 0.04), -- CO para Dispositivo 2
(9, 0.01); -- CO para Dispositivo 3
```